SpO2 Sensors for RVS 100 Advanced Vital Signs Monitor
347,47 лв. Select options

SpO2 Sensors for RVS 100 Advanced Vital Signs Monitor

347,47 лв.

SpO2 Sensors for RVS 100 Advanced Vital Signs Monitor

Riester SpO2

  • Measurement range: 0 – 100%
  • Resolution: 1%
  • Accuracy:
    • ±2% (70 to 100%)
    • ±3% (40% to 69%)
    • Unspecified (0% to 39%)
  • Alarm range: 0 – 100%
  • Average time: 4 sec, 8 sec, 16 sec
  • Pulse rate
    • Measurement range: 20 – 250 bpm
    • Resolution: 1 bpm
    • Accuracy: ±1% or ±1 bpm whichever is greater
Nellcor SpO2
  • Measurement range: 0-100%
  • Resolution: 1%
  • Accuracy:
    • 70 – 100%: ±2% (adult, pediatric)
    • 70 – 100%: ±3% (neonate)
    • Unspecified (0 – 69%)
  • Alarm range: 0 – 100%
  • Average time: 8 sec, 16 sec
  • Pulse rate
    • Measurement range: 20 – 300 bpm
    • Resolution: 1 bpm
    • Accuracy:
      • 20 – 250 bpm: ±3 bpm
      • 251 – 300 bpm: unspecified
Masimo SpO2
  • Measurement range: 0 – 100%
  • Resolution: 1%
  • Accuracy:
    • 70 – 100%: ±2% (adult, pediatric, non-motion conditions)
    • 70 – 100%: ±3% (neonate, non-motion conditions)
    • 70 – 100%: ±3% (motion conditions)
    • 0 – 69%: unspecified
  • Average time: 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec
  • Pulse rate
    • Measurement range: 25 – 240 bpm
    • Resolution: 1 bpm
    • Accuracy:
      • ±3 bpm (non-motion conditions)
      • ±5 bpm (motion conditions)
SKU: N/A Categories: ,

SpO2 Sensors for RVS 100 Advanced Vital Signs Monitor

Riester SpO2

  • Measurement range: 0 – 100%
  • Resolution: 1%
  • Accuracy:
    • ±2% (70 to 100%)
    • ±3% (40% to 69%)
    • Unspecified (0% to 39%)
  • Alarm range: 0 – 100%
  • Average time: 4 sec, 8 sec, 16 sec
  • Pulse rate
    • Measurement range: 20 – 250 bpm
    • Resolution: 1 bpm
    • Accuracy: ±1% or ±1 bpm whichever is greater
Nellcor SpO2
  • Measurement range: 0-100%
  • Resolution: 1%
  • Accuracy:
    • 70 – 100%: ±2% (adult, pediatric)
    • 70 – 100%: ±3% (neonate)
    • Unspecified (0 – 69%)
  • Alarm range: 0 – 100%
  • Average time: 8 sec, 16 sec
  • Pulse rate
    • Measurement range: 20 – 300 bpm
    • Resolution: 1 bpm
    • Accuracy:
      • 20 – 250 bpm: ±3 bpm
      • 251 – 300 bpm: unspecified
Masimo SpO2
  • Measurement range: 0 – 100%
  • Resolution: 1%
  • Accuracy:
    • 70 – 100%: ±2% (adult, pediatric, non-motion conditions)
    • 70 – 100%: ±3% (neonate, non-motion conditions)
    • 70 – 100%: ±3% (motion conditions)
    • 0 – 69%: unspecified
  • Average time: 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec
  • Pulse rate
    • Measurement range: 25 – 240 bpm
    • Resolution: 1 bpm
    • Accuracy:
      • ±3 bpm (non-motion conditions)
      • ±5 bpm (motion conditions)

Additional information

Modules

SpO2 Sensor Riester Neonatal for RVS-100